Cleanliness and Physical properties of Poly Ethylene CLEAN BAG

 

 
GRADE AFB-01 ADF-03 PAS-05 LAS-04 General
PE Bag
Thickness(㎛) 60 60 60 60 60
Cleanliness
(Particles/㎠)
0.1 ㎛ < 49.5 113.3 216.4 NG
0.2 ㎛ <
10,000 ≤

NG
0.2 ㎛ <
10,000 ≤

0.2 ㎛ < 11.0 29.9. 16.7
0.3 ㎛ < 2.8 7.9 2.5

Tensile Strength
(Kgf/㎠)

MD 184 180 271 312 163
TD 163 161 296 277 189

Elongation (%)

MD 632 581 504 1036 396
TD 868 845 618 1020 683

Modulus
(Kgf/㎠)

MD 1959 1521 2436 1311 1141
TD 2262 1750 2635 1312 921

Seal Strength
(Kgf/10㎜)

  1.31 1.05 1.18 1,18 0.47

Surface Resistance(Ω)

  < < < ~< <

※ Above data is representative test data and not a guarantee level. Measured by the measuring method of AicelloMilim Chemical Co., Ltd.

 

Metal Ion Analysis on Polyethylene CLEAN BAG

 

Measuring Instrument: ICP-MS Unit: ppb  

GRADE AFB-01 ADF-03 PAS-05
Na < 0.1 < 0.1 < 0.1
Mg < 0.1 < 0.1 < 0.1
Al < 0.1 < 0.1 < 0.1
K < 0.1 < 0.1 < 0.1
Ca < 0.1 < 0.1 < 0.1
Cr < 0.1 < 0.1 < 0.1
Mn < 0.1 < 0.1 < 0.1
Fe < 0.1 < 0.1 < 0.1
Ni < 0.1 < 0.1 < 0.1
Cu < 0.1 < 0.1 < 0.1
Zn < 0.1 < 0.1 < 0.1

※ Above data is representative test data and not a guarantee level. Measured by the measuring method of Aicello Milim Chemical Co., Ltd.
※ Measuring method :  
(1)Fill D.I. water 250ml into the CLEAN BAG with internal surface of 500㎠,
(2)Rotate 3 times as wash the film inside
(3)leave it for 24 hours
(4)measure the metal ions in D.I. water with ICP-MS

 

Cleanliness and Physical properties of Poly Nylon CLEAN BAG

 

GRADE

Aicello Milim Nylon Clean Bag

Thickness(㎛)

50

Cleanliness (Particles/㎠)

0.1 ㎛ < 40.7
  0.2 ㎛ < 8.9
  0.3 ㎛ < 1.7

Tensile Strength (Kgf/㎠)

MD 852
TD 821

Elongation (%)

MD 285
TD 309

Modulus (Kgf/㎠)

MD 7482
TD 6271

Seal strength (Kgf/10㎜)

  1.21

Surface Resistance (Ω)

 

Clarity (HAZE)

  12.3

※ Above data is representative test data and not a guarantee level. Measured by the measuring method of Aicello Milim Chemical Co., Ltd.

 

Metal Ion Analysis on Nylon CLEAN BAG I

Lab Service : Eco Research

Unit : ppb(ng/g), Instrument : ICP-MS  

GRADE

Aicello Milim Nylon Clean Bag

Be 0.001
Na 0.076
Mg 0.017
Al

0.020

K

0.084

Ca

0.289

Ti 0.001
Cr 0.018
Mn

0.001

Fe

0.149

Co

0.001

Ni

0.048

Cu

0.011

Zn

0.046

Ga 0.001
Mo 0.001
Ba 0.008
W 0.001
Pb 0.012
Total 0.793

※ Measuring method :
Fill 0.02% HNO3 500ml into the CLEAN BAG with internal surface of 2660㎠, leave it for 1 hour, and measure the metal ions with ICP-MS
※ Above data is representative test data and not a guarantee level. Measured by the measuring method of Aicello Milim Chemical Co., Ltd.

 

Metal Ion Analysis on Nylon CLEAN BAG II

Lab Service : Balazs Nanoanalysis

Unit : Atoms/cm², Instrument : ICP-MS  

Analyte

LAM 202F Spec

Nylon CLEAN BAG

LAM 202F Spec Pass

Aluminum

1.00E+13

*

Pass

Calcium

2.00E+13

*

Pass

Chromium

1.00E+12

*

Pass

Cobalt

1.00E+12

*

Pass

Copper

1.00E+12

*

Pass

Iron

1.00E+13

2.19E+11

Pass

Lithium

5.00E+12

*

Pass

Magnesium

2.00E+12

*

Pass

Molybdenum

1.00E+12

*

Pass

Nickel

1.00E+12

*

Pass

Potassium

5.00E+12

1.20E+12

Pass

Sodium

1.00E+13

1.15E+12

Pass

Titanium

1.00E+12

*

Pass

Zinc

1.00E+13

*

Pass

Measuring method : Fill 0.02% HNO3 500ml into the CLEAN BAG with internal surface of 2660㎠, leave it for 1 hour, and measure the metal ions with ICP-MS

 

The oxygen penetration ratio of CLEAN BAG

unit : cm³/(m².day.atm)  

Grade

The oxygen penetration ratio

Nylon CLEAN BAG 15
AFB-01 1300
ADF-03 2000

※ Above data is representative test data and not a guarantee level. Measured by the measuring method of Aicello Milim Chemical Co., Ltd.

 

Cleanliness Measuring Method for CLEAN BAG

AICELLO MILIM Measuring Method

1)

Fill the D.I. water to the specified size of measurement sample (internal surface area 500㎠)

2)

Rotate 3 times as wash the film inside.

3)

After leaving it for 40 minutes, measure the number of particles with fluid particle counter

 

※After taking 5 ㎖ of sampling liquid, measured with total number counter method for 3 times, and the average is treated as the measured data

4)

Calculate the cleanliness level per film surface area by applying measured data to the formula below:

 

Cleanliness level
(Number of particles/㎠)

=

Measured data (number) X 250 ㎖

Amount of sampling liquid(=5 ㎖ ) X 500 ㎠


 